INSTALLATION

WARNING: Read all instruc-

tions completely and thoroughly

before attempting installation.

Failure to do so could result in

serious injury, property dam-

age or loss of life. Operation of

improperly installed and main-

tained venting system could

result in serious injury, property

damage or loss of life.

NOTICE: Failure to follow these in-

structions will void the warranty.

VENTING INSTALLATION
PRECAUTIONS

Consult local building codes before beginning the

installation. The installer must make sure to select

the proper vent system for installation. Before

installing vent kit, the installer must read this

fireplace manual and vent kit instructions.
Only a qualified service person should install

venting system. The installer must follow these

safety rules:
• Wear gloves and safety glasses for protection
• Use extreme caution when using ladders or

when on roof tops

• Be aware of electrical wiring locations in walls

and ceilings

The following actions will void the warranty on

your venting system:
• Installation of any damaged venting component
• Unauthorized modification of the venting system
• Installation of any component part not manu-

factured or approved by DESA

• Installation other than as instructed by these

instructions

WARNING: This gas fireplace

and vent assembly must be

vented directly to the outside. The

venting system must NEVER be

attached to a chimney serving a

separate solid fuel burning appli-

ance. Each gas appliance must

use a separate vent system. Do

not use common vent systems.

WARNING: Horizontal sec-

tions of this vent system require

a minimum clearance of 2" from

the top of the pipe and 1" mini-

mum to the sides and bottom.

Vertical sections of this system

require a minimum of 1" clear-

ance to combustible materials

on all sides of the pipe.

VENTING INSTALLATION

1. Install elbow to fireplace collar adapter located

on back of the unit at a 45° angle. Slide elbow

over collar and twist to lock. Check to insure

proper connection (see Figure 6).

2. Continue to install remainder of pipe for

desired installation. Make sure each section

is twist-locked securely.

3. When installation of vent pipe is complete, in

stall vent termination. Depending on the loca-

tion of your fireplace, you will vent vertically

or horizontally.

4. Allow 1" of pipe to protrude from internal

wall, depending on wall thickness. See

Figure 7, page 8.

5. For horizontal installation, an optional siding

standoff may be installed between the vent cap

and the exterior wall. Secure horizontal vent cap

to standoff. Secure standoff/vent cap assembly

to wall (see Figure 7, page 8). Do not seal termi-

nation to vent pipe. The vent termination must

be removable for service pipe inspection.

Figure 6 - Venting Installation

Female
Locking Lugs

Male
Locking Lugs

Vertical Flue
Restrictor
(For Vertical
Venting
Application)

This manual is related to the following products: