Technical Data
•
Mounting: Vertical.
•
Connection: DN-40 PN-16 DIN 2501 Flange.
R 1½” BSP thead.
(Others available on request).
•
Maximum length: AISI-316 ... 6000 mm.
PVC, PTFE ... 2500 mm.
PVC, PTFE ... 6000 mm
(internal AISI-316).
•
Precision: ± 2 mm.
•
Hysteresis: ± 4 mm.
•
Working pressure:
PN-16 AISI-316.
PVC, PTFE with internal AISI-316 tube.
PN-10 PVC, PTFE.
•
Liquid temperature:
-20ºC...+150ºC en AISI-316, PTFE.
0ºC...+50ºC PVC.
•
Ambient temperature:
-20ºC...+60ºC AISI-316, PTFE.
0ºC...+50ºC PVC.
•
Liquid density: From 0,45 to 3 kg/l.
•
Liquid viscosity: Maximum 1500 cSt.
•
Contacts: Reed 1 A 220 V.
(maximum 9 with minimum separation
of 20 mm)
Conforms with Directive 73 / 23 / CEE
2
No.
Piece
Materials
LC-.../INOX
LC-.../PVC
LC-.../PTFE
1
Enclosure
DIN 43650/
Aluminium
DIN 43650/
Aluminium
DIN 43650/
Aluminium
2
Connection
AISI-316
PVC
PTFE
3
Rod
AISI-316
PVC
PTFE
4
Float
AISI-316
PVC
PTFE
5
Magnet
Alnico
Alnico
Alnico
6
Reed switch
-
-
-
7
Float stop
AISI-316
PVC
PTFE
CONSTRUCTION
OPERATION
Inside the guide tube, reed switches are mounted at the
alarm/control points..
As the float passes the position where a reed switch is
located, the magnetic field from the float actives the switch.
The maximum number of alarm or control points is 9.