Working Principle

The flowmeter consists of a float inside a conical tube.
The rising flow pushes the float to an equilibrium point.
The area obtained between the float and the orifice is
proportional to the flow rate.

This type of measuring principle is known as variable
area.

The equilibrium point depends on :

− The float weight

:

Pf

− The fluid thrust :

E

− The free flow area : Al

The area proportional to the flow rate will be:

Al = Ac - Af

where:

Ac = Flow measuring tube area

Af = Float area

Each position of the float corresponds to a flow rate
indicated on the scale printed on measuring tube.

Reading
line (see
page

3)

2

n.

Part

Materials

1

Body

EN 1.4404

2

M. Tube clamp

EN 1.4404

3

O-ring

NBR

4

End gasket

NBR

5

Top spring

EN 1.4401

6

Float

EN 1.4404 /

Glass / Ceramic /

Hostalen

7

Measuring Tube

Borosilicate Glass

8

Bottom spring

EN 1.4401

9

Transparent

protection

Metacryilate

10

Screw

Nylon ®