Rear panel, Connection cables, Cable specifications – Teac RC-SS20 User Manual
Page 4: 2–names and functions of parts, L = 10 m or less, Rear panel connection cables
4
TASCAM RC-SS20
2–Names and Functions of Parts
Rear panel
Connection cables
Cable specifications
D-SUB25
Male (Plug)
D-SUB25 Male (Plug)
UL2464 AWG24
Screw
:#4-40 (inch)
Screw
:#4-40 (inch)
Ground Shield
(Connect to Connector Frame)
L = 10 m or less
1
REMOTE 1 connector
Connect an SS-R1 or SS-CDR1..
2
REMOTE 2 connector
Connect an HD-R1.
CAUTION
Do not connect devices to both the REMOTE 1 connec-
•
tor and the REMOTE 2 connector at the same time.
Turn OFF the power of the SS-R1, SS-CDR1 or HD-R1
•
unit before connecting or disconnecting the connection
cable. Connecting or disconnecting the cable while the
power is ON could cause malfunction.
The PW-SS20 connection cable designed for this unit
is available for purchase separately. Please inquire at a
retail shop or TASCAM sales office.
If you choose to make your own cable, please make
it with straight wiring between D-SUB 25-pin
connectors based on the following specifications.
D-SUB connector
Case: Hirose Electric HDB-CTH1 (4-40) or equivalent
Plug: Hirose Electric HDBB-25P (05) or equivalent
Cable UL2464 AWG24
Hitachi Cable UL2464-SB 25P x 24AWG(7/0.203) LF
or equivalent
Length
10 m or less
Wiring
Straight connections for all pins 1–25