7.

Install ceiling template by sliding lower duct over
upper duct. See FIG. 11.

If bolts are left loose there may not be an ad-
equate roof seal or if over tightened, damage
may occur to the air conditioner base or ceil-
ing template. Tighten to torque specifications
listed in this manual.

CAUTION

FIG. 11

Slide Lower Air
Discharge Duct
Over Upper Duct

Roof

Hold Ceiling Template With
One Hand And Install 3
Mounting Bolts Finger Tight

Air Conditioner
Return Air
Opening

8.

Hold the ceiling template with one hand and with the
other, install the three 1/4" mounting bolts through
the template and into the base pan.

a.

Finger-tighten the bolts and check alignment.
There should be an equal opening on each side
and the rear flange must be tight against the roof
opening.

b.

EVENLY tighten the three bolts to a torque
of 40 to 50 inch pounds. This will compress
the roof gasket to approximately 1/2". The
bolts are self locking so over tightening is
not necessary.

G. Wiring The System

Disconnect 120 volt AC. Failure to follow these
instructions could create a shock hazard caus-
ing death or severe personal injury.

WARNING

!

Reach up into the return air opening and pull the re-

maining wires down.
1.

Connection of 120 VAC (refer to FIG. 12)
a.

Route power supply line through Romex con-
nector into junction box. Tighten connector,
being careful not to pinch or short wires.

b.

Connect white to white; black to black; and
green to green or bare copper wire using appro-
priate sized twist connectors.

c. Tape the twist wire connectors to the supply

wire to assure they don't vibrate off.

d. Push the wires into the box.
e. Install the cover onto the junction box.

Note: If optional electric heater is part of this installation, now
is the time to install it. Installation instructions are provided
with the electric heater kit.

f.

Plug the electrical conduit from the upper unit
into the mating switch box connector. See FIG.

12.

FIG. 12

Route Power Supply
Through Romex Con-
nector

Plug Conduit
Into Switch
Box

I n s t a l l
Cover

600312 & 600315 Series Installation Instructions