SDB Status Register
SDBA_STAT 0x03480000
SDBB_STAT 0x03580000
31–30 29
28 27 26 25 24
23–16
IFLAG OFLAG IFF IFE OFF OFE
IFL
R,0 R,1
R,0
R,1
R,0
R,1
R,00000000
15–8 7
6
5
4
3 2 1 0
OFL TRANS
PRI DIS
SDBCLK
CLRIF CLROF DIR
R,11111111 RW,0
RW,0
RW,0 RW,0 W,0 W,0 R,0
Field
Description (flags are active when 1)
0 Reading
DIR Transfer
direction
1 Writing
CLROF
Clear outgoing FIFO
CLRIF
Clear incoming FIFO
0 50MHz
SDBCLK SDB clock speed
1 100MHz
0
Pause transmission when FIFO is full
DIS
1 Continue
transmission even when FIFO full
0 Transmitter
wins
PRI
Priority for changing direction of transfer
1 Equal
priority
TRANS
Set to 1 after reset to make this SDB start as a transmitter
OFL
Outgoing FIFO Level: number of words that can be written
IFL
Incoming FIFO Level: number of words that can be read
OFE
Outgoing FIFO Empty
OFF
Outgoing FIFO Full
IFE
Incoming FIFO Empty
IFF
Incoming FIFO Full
OFLAG
Outgoing FIFO Flag. Set when OFLAGLEVEL writes can be performed.
IFLAG
Incoming FIFO Flag. Set when IFLAGLEVEL reads can be performed.