Figure 3 Dip Switch Settings


Switch

Switch

Description

Function

Default

Setting

Number

Position

1

OFF

Remote Switch Logic

Turns pump off when terminals

connect.

OFF

1

ON

Remote Switch Logic

Turns Pump on when terminals

connect.

OFF

2

OFF

Low Water Cutoff Logic

Turns pump off when terminals

connect.

OFF

2

ON

Low Water Cutoff Logic

Turns pump on when terminals

connect.

OFF

3

ON

Input Voltage Thresholds

Adjust 1

Reduces the input voltage

requirements See Table 2

OFF

4

ON

Input Voltage Thresholds

Adjust 2

Reduces the input voltage

requirements See Table 2

OFF

5,6

Not used at this time

Should be in the off position for

proper operation

OFF

7

ON

Display Freeze

Holds display on current screen

OFF

8

ON

Battery Protection Override

Disables the battery bank

protection.