beautypg.com

Studio Technologies 85 User Manual

Page 9

background image

Model 85 User Guide

Issue 4, June 2011

Studio Technologies, Inc.

Page 9

120, or 220/240 Vac, 50/60 Hz is required.

Confirm what mains voltage is required by

observing the selection boxes to the left

of the AC mains connector on the back

panel. Whenever mains power is con-

nected the power present LED should be

lit. If the LED is not lit confirm that the main

power source is active (“hot”) and that the

connector on the cord is securely mated

with the plug on the back panel.
For safety in the event of a major internal

failure or the connection of incorrect AC

mains voltage, the Model 85 contains a

fuse inside the cabinet. The fuse will open

(“blow”) if the failure of an internal com-

ponent causes excessive current to be

drawn from the internal power supply. The

fuse will also open should 220/240 Vac be

connected to a Model 85 that is configured

for 100 or 120 Vac operation. The fuse is

intended to be replaced only by a qualified

service technician. This person will have

the training to safely access the “guts” of

the Model 85 and identify where a problem

is located.

If Signal Doesn’t Seem to Be Present

on the Outputs
Valid outputs depend on a valid input

source. Ensure that the signal present

LEDs are lit in response to what you con-

sider valid input signals. Should a signal

present LED not be lit confirm that the

source is operating and the cabling has

been correctly prepared. On the front

panel, check the output source selection

switches to confirm the correct settings.