beautypg.com

Vented type decorative appliance evgl850n, Troubleshooting, Continued – Desa EVGL850N User Manual

Page 16

background image

16

107050

VENTED TYPE DECORATIVE APPLIANCE

EVGL850N

®

TROUBLESHOOTING

Continued

WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating fireplace where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors.

POSSIBLE CAUSE

1. Metal expanding while heating or con-

tracting while cooling

1. Fireplace burning vapors from paint, hair

spray, glues, etc. (See

IMPORTANT

statement above)

2. Gas leak.

See Warning statement at

top of page

1. Gas leak.

See Warning statement at

top of page

2. Control valve defective

1. Foreign matter between control valve

and burner

2. Gas leak.

See Warning statement at

top of page

1. Improper log placement
2. Air holes at burner inlet blocked

3. Burner flame holes blocked

OBSERVED PROBLEM

Fireplace produces a clicking/ticking noise
just after burner is lit or shut off

Fireplace produces unwanted odors

Gas odor even when control knob is in OFF
position

Gas odor during combustion

Dark residue on logs or inside of fireplace

REMEDY

1. This is common with most fireplaces. If

noise is excessive, contact qualified ser-
vice person

1. Ventilate room. Stop using odor caus-

ing products while fireplace is running

2. Locate and correct all leaks (see Gas

Line Hook-Up, page 9)

1. Locate and correct all leaks (see Gas

Line Hook-Up, page 9)

2. Replace control valve

1. Take apart gas tubing and remove for-

eign matter

2. Locate and correct all leaks (see Gas

Line Hook-Up, page 9)

1. Properly locate logs (see Log & Ember

Placement, page 10)

2. Clean out air holes at burner inlets. Pe-

riodically repeat as needed

3. Remove blockage or replace burner

www.desatech.com