15-619 CHEMICAL CLEANLOAD PART LIST
REF#
PART #
DESCRIPTION
QUANTITY
1
8897-25
1
1
/
4
" Discharge Hose 25"
1
2
18-116
Hose Clamp
4
3
16-156
90° Hose Barb
3
4
18-391
Coupling
1
5
15-620
Cleanload Assembly
1
6
HBFL-516-18-075
Flange Bolt,
5
/
16
- 18 x ¾
4
HNFL-516-18
Flange Lock Nut,
5
/
16
- 18
4
7
15-816
Mixer Mount
1
8
8897-88
1
1
/
4
" Discharge Hose 88"
1
9
16-880
Close Nipple
1
10
18-390
Pipe tee
1
11
HB-38-16-300
Hex Bolt,
3
/
8
- 16 x 3
1
HNTL-38-16
Lock Nut,
3
/
8
- 16
1
12
16-159
Fitting
1
13
16-945
Fitting
(part of tank)
INSTALLATION INSTRUCTIONS
1. Make sure sprayer tank is empty and flush all chemical residue from sprayer. Always wear protective
clothing, goggles and gloves.
2. Disconnect outlet hose from the spray pump then the 90° fitting from the pump.
3. Install the close nipple, tee, elbow and the 90° elbow that was removed from the pump. Always use thread
sealant on all fittings. Tighten all Fittings. One of the 90° fittings should point towards the right side of the
machine and the other one needs to point to the back of the machine.
4. Reinstall the outlet hose onto the spray pump and tighten hose clamp.
5. Install 88" of 1
1
/
4
" suction hose onto the elbow on the pump that points back and tighten hose clamp.
6. Route the 88" hose to the back of the sprayer so it connects over the top of the left boom support tube.
7. Install Mixer Mount (Ref 7) onto the left hand side of the center boom section. The Mount will slide over
the 2" tube under the actuator. Secure Mixer Mount with
3
/
8
x 3 bolt and lock nut. Tighten.
8. Mount Cleanload Assembly onto mixer mount using
5
/
16
x
3
/
4
flange bolts and flange nuts. Tighten.
9. Install 18-391 reducer coupling (Ref 4) onto outlet side. Then a 16-156 90° elbow (Ref 3) into the coupling
pointing up and one into valve with yellow handle. Tighten fittings so that the elbow in the valve is pointing
up and forward. The outlet fitting should be pointing up.
10. Remove the plug from the top back of the spray tank and install 16-159 hose barb (Ref 12) and tighten.
Now the 25" hose can be installed from the tank to the outlet fitting and tighten with clamps.
11. The hose from the spray pump can be connected to the inlet fitting and tightened with clamps.
12. Make sure all hardware, fittings and clamps are tight. Add about 25 gallons of water to the spray tank.
Start sprayer and circulate water through system to check for leaks.
13. Be sure to read start up, loading and shutdown instructions for Cleanload Assembly before using with
chemicals. When working with chemicals Always wear protective clothing, goggles and gloves.