Chapter 5: Communication Protocol

The command to make the end of CAT5 line receiver (SLRX-RX300) switch between its local and remote sources is
as follows;
<0xBE><0xEF>
Where;
<0xBE>

always

0xBE

<0xEF>

always

0xEF

Frame address. Set by Hex switch on unit or position in Rack frame.

always

0x00

50 (0x32)
is Two bytes 0L = Receiver LOCAL Video/Audio, 1 = Receiver
REMOTE Video/Audio

So if switching the Receiver on output 3 of Frame 2 to its local source send
<0xBE><0xEF><0x02><0x00><0x32><0x02><0x63>

Get System Information
Cmd = 0xff
Databytes = NULL (none)

Unit will return a valid PSU as detailed above where Databytes are as follows

, ,

Where Product Type =
1 Byte;
0 = SmartNet V
1 = SmartNet X
3 = SLX-TX550
4 = SLX-RX300

Where Switch configuration =
2 Bytes;

Where Version =

3 bytes

Appendix A: RS232/422 Converter and Comms Cable

RS232/RS422 Converter

A suitable RS232/RS422 product can be purchased from KK Systems in Brighton, East