Semi-permanent installation, E1 e double window – DeLonghi PINGUINO PAC T110P User Manual
Page 6
![background image](/manuals/78754/6/background.png)
6
I n s t a l l i n g y o u r p o r t a b l e
a i r - c o n d i t i o n e r
SEMI-PERMANENT INSTALLATION
If required, the Pinguino can also be installed
semi-permanently (Fig. E and E1).
•
Fit the flange accessory (11) provided in
the hole.
•
Fit the hose (12/19) in the housing at the
back of the appliance (fig. A / A1 page 5).
•
Fit the end of the hose (12/19) to the flan-
ge (11) as shown in fig. G.
Proceed as follows:
•
Drill a hole in an outside wall or through a
window pane.
Respect the height and dimensions of the
hole (s) given in figures F and G.
30 cm
11.8 in
ches
30
cm
11,8 inches
MAX100 cm
MIN 35 cm
MAX 39.37 inches
MIN 13.77 inches
When the hose (12/19) is not fitted, the drilled
hole can be closed with the flange cap (11).
NOTE.
When installing the air conditioning unit semi-
permanently, you should leave a door slightly
open as little as 1/2 inches (1 cm) to gua-
rantee correct ventilation.
G
Keep the air hoses as short and free of
curves as possible to avoid constrictions.
4.17 inc
hes (106 mm)
in the window
pane
in the wall: you are
recommended to
insulate the sec-
tion of wall using
suitable insulation.
in the woo-
den kick-
board of a
French win-
dow
F
30 cm
11.8
inches
30
cm
11,8 inches
E1
E
Double window
Open the double window slightly and posi-
tion the window outlet (13) .
Use the suction pads (14) or (22) (depending on
model) to hold the two parts of the window
together (fig. D and D1).
D1
1
2
D