SETTING THE BURNER MINIMUM

When switching from one type of gas to another, the minimum flow rate must also be
correct: the flame should not go out even when passing suddenly from maximum to
minimum flame.
To regulate the flame follow the instructions below:

Semirapid and triple ring burners

– Light the burner
– Set the gas valve to

position

– Remove the knob
– With a thin screwdriver pass by the hole of microswitch and turn the screw F until

adjustment is correct (fig. 2.7).

Inside crown of DUAL burner

– Light the DUAL burner
– Set the gas valve to

position

– Remove the knob
– Using a screwdriver turn the screw H until the correct setting is obtained (fig. 2.8).

Outside crowns of DUAL burner

– Light the DUAL burner
– Set the gas valve to

position

– Remove the knob
– Using a screwdriver turn the screw G until the correct setting is obtained (fig. 2.8).

For LP/PROPANE gas, tighten the adjustment screws completely.

Fig. 2.7

Fig. 2.8

F

G

H