beautypg.com

DeLonghi DEFSGG 36 User Manual

Page 19

background image

19

1

2

NATURAL GAS

REGULATION

LP/PROPANE

REGULATION

A
component

Fig. 2.5

REGULATOR
COVER

Pressure
regulator

CONVERSION TO LP/PROPANE GAS

Every range is provided with a set of injectors for the various types of gas.

Select the injectors to be replaced according to the “INJECTORS TABLE”.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the
body of each injector.

SETTING THE PRESSURE REGULATOR

(fig. 2.5)

The pressure regulator is accessible through the storage compartment by opening
the bottom pivoting panel; the pressure regulator is positioned on the rear right side
of the range.

To set the pressure regulator:

1. Unscrew the regulator cover;

2. Unscrew the A component, reverse and screw it according to the LP/PROPANE

regulation.