Remko, Ets 300, Operation – REMKO ETS300 User Manual
Page 6: Decommissioning, Care and maintenance

6
REMKO
ETS 300
Operation
Manual operation is not necessary.
Decommissioning
Temporary shutdown
1.
If necessary, disconnect the electrical
connection of the flange heating
cartridge at all poles.
2. Drain the tank in areas where
it is at risk from frost and before
the onset of winter.
3. After closing the shut-off valve
in the cold water supply, the water
is drained through the drain valve
of the safety combination while
all the hot water valves of the service
water fixtures are open. Partial
emptying is also possible through
the safety valve in the expansion
water funnel (drip catcher). For this
purpose the safety valve is turned
to the "Test" position.
!
ATTENTION
When emptying the tank, hot
water may escape!
!
ATTENTION
When placing the tank back into
service, ensure that it is filled with
water and that water which is free
of bubbles is escaping from the
valves!
Permanent decommissioning
Ensure that equipment and components
are disposed of in accordance with local
regulations, e.g. through authorised
disposal and recycling specialists
or at collection points.
REMKO GmbH & Co. KG or your
contractual partner will be pleased
to provide a list of certified firms in your
area.
Care and maintenance
Care
■
Clean the units with a damp cloth.
(adding, for instance, a liquid
household cleaner).
Do not use any caustic, abrasive
or solvent-based cleaning products.
Maintenance
■
It is recommended that you take out
a maintenance contract with
an annual service from
an appropriate specialist firm.
The tank has connections for circulation
(3/4" IG) as well as a cold water supply
and hot water outlet (1" IG).