Commissioning – REMKO CLK 20 User Manual

Page 8

background image

8

Commissioning


Someone who has been sufficiently trained in the corre-
sponding handling of the unit must be assigned with its
operation and monitoring.

Important notice before the startup of a cold unit
The preheating of the nozzle stock delays the start of
the unit dependent on temperature.

Connecting the unit to the power supply

1. Switch the operating switch to the "0" position (off).

2. Connect the mains plug of the unit only to a properly

installed and sufficiently secured mains socket.

3. Open all shut-off fittings in the oil supply.

When operating the unit for the first time, air in the oil
supply can cause the burner to shut down due to a
malfunction.

Ventilation

In this switch position, only the supply air fan runs and
the unit can be used for air circulation.

1. Turn the operating switch to the "II" position

(ventilation).

2. Please note: in this mode, regulation of the

thermostat and heating mode are not possible.

1. Connect the jumper plug (2) in-
cluded in delivery with the thermostat
socket (1) on the unit.
2. Switch the operating switch to the
"I" position (heating).

Heating without room thermostat

The equipment works in continuous operation.

1

2

1. Disconnect jumper plug 2.

2. Connect the plug (3) of the room ther-

mostat (4) together with the thermo-
stat socket (1) of the device.

Fully automatic heating with room thermostat

The unit operates fully automatically depending on the
room temperature.

1

3

4

Hot air distribution

The units are equipped with a high-performance axial
fan. This fan has been designed to transport the hot air
directly and effectively.
The distribution of the air should preferably take place
using the on-site outlet nozzle.
If necessary, pipes or special hot-air or foil hoses for air
distribution in the possible area of fan output (observe
the channel resistance/equipment compression).
◊ Use only hot air hoses (accessories) approved by

Remko. In the process, pay attention to the air direc-
tion!

◊ To prevent heat from building up, the pipes and

hoses may not have sharp kinks and bends.

◊ Counterpressure may not be allowed to build up

when using hoses to heat enclosed spaces.

If suction temperatures increase or if there is resistance

at the air output opening, the forced-air burner can
be switched off at short notice by the temperature
monitor (TW) during heating.
When the temperature falls, the burner restarts auto-
matically.

◊ If the intervals are too short, the length of the hot air

pipes and hoses should be checked.

Avoid starting the burner in frequent cycles (run
times under five minutes).

If the temperature becomes too high, the heating
mode is interrupted permanently by the STB!

Control panel

Jumper plug

Thermostat socket

„Burner“ reset button

„Burner Fault“ red control lamp

Operating

„Operation“ green control

Safety temperature limiter

Note about the "Operation" control lamp
The control lamp indicates that the unit is in "

Heating"

mode.

When the unit is in "

Ventilation

"

mode, nothing is displayed

3. Place the room thermostat in a suit-
able spot.

The thermostat sensor may not be

located within the flow of warm air and
may not be directly attached to a cold
foundation.

4. Adjust the desired temperature on
the room thermostat.
5. Switch the operating switch to the
"I" position (heating).

If heat is needed, the forced-air

burner switches on automatically and
the unit functions fully automatically.