Technical Data

Model

CLK 20

Max. nominal heat load

kW

22

Nominal heat output

kW

20

Nominal air volume flow

m³/h

1.860

Pressure (max. total)

Pa

95

Fuel

EL heating oil or diesel according to DIN 51603 or
diesel fuel

Max. fuel consumption

L/h

2.20

Oil nozzle (Danfoss)

2)

USG

0.5/60°S

Pump pressure, approx.

2)

bar

10.5 – 11.0

Max. chimney loss

%

9

Chimney volume, approx.

kg/h

35

Furnace resistance, approx. (start/operation)

Pa

140/40

Required chimney draft

Pa

0

Electrical connection

V/Hz

1~ 230/50

Max. power consumption (ges. Gerät)

W

320

Max. nominal current

(ges. Gerät)

A

1.45

Max. power consumption (Ventilator)

W

130

Max. nominal current

(Ventilator)

A

0.6

Operating capacitor of the fan

µF

3

Fuse protection (on site)

A

10

Temperature increase (

t

)

K

41

Sound pressure level L

pA

1m

3)

dB (A)

60

Air outlet ø

mm

300

Chimney adapter Ø

mm

130

Total unit length

mm

1.180

Total unit width/with wheel attachment

mm

510/580

Total unit height/with wheel attachment

mm

735/880

Weight with forced-air oil burner

kg

94

2) The listed nozzle sizes and pump pressures were determined on the basis of adjustment tests on a test stand. The oil throughput was meas-
ured out.

(The specifications serve only as standard values due to product-specific nozzle and pressure tolerances and oil temperatures.)

3) Noise measurement according to DIN 45635 - 01 – Cl. 3 (without burner operation)

We reserve the right to make changes in dimensions and design in the interest of technical advances.