Troubleshooting

Unit (fan) does not start:

1. Check main fuse

2. Check connecting cable with plug

3. Check operating switch

4. Check slight drifting of fan (motor)

Unit does not heat

1. Check operating switch

2. Check function of the two temperature limiters.

4. Check room thermostat

5. Check room thermostat-operation: thermostat must

be set higher than the room temperature

Series

TX9000

Nominal heat output

kW

9,0

Switchable heat output

kW

2 x 4,5

Air output

m³/h

600

Electrical connection

V

400, 3~, PE

Frequency

Hz

50

Rated current max.

A

13,2

Power consumption max.

kW

9,15

Fuse protection (required)

A (inert) 16

Sound pressure level L

pA

1m

1)

dB (A)

53

Dimensions Length

mm

510

Width

mm

300

Height

mm

455

Weight

kg

14,7

1) noise measuring DIN 45635 - 01 - KL 3

Technical Data

Should the unit still not be working despite these checks,
please contact an authorised service centre.

Wiring Diagram

L3

6

PE

N

L1

L2

A2

A1

5

1

3

13

6

2

4

14

d

f

e

a

a

4

6

5

1

2

TB1

X1

TB2

S

RT

NK

ϑ

ϑ

ϑ

ϑ

400 V

R1
bis
R3

R4
bis
R6

K1

M

L3

PE

L1

L2

X2

K1

contactor

M

fanmotor (400 V)

NK

recool thermostat (37°C)

R1 to R3

heating elements 1. step

R4 to R6

heating elements 2. step

RT

room thermostat

S

operating switch

TB1

temperature limiter (77°C)

TB2

temperature limiter (70°C)

X1

terminal strip

X2

CEE-mains plug

Prior to starting any work make sure to pull the
mains plug out of the mains socket!
Setting and maintenance is to be carried out
only by authorised experts!

R1
to
R3

R4
to
R6

S 0

1

a

2

a

4

d

5

e

6

f

1 2 3

Schaltspiegel

Betriebsschalter

schematic diagram

operating switch

We reserve the right to make modifications in dimensions and construction in the interests of technical progress.