Service and guarantee – REMKO PGT 30 User Manual
Page 9
9
Adjustment instructions:
Dimension A = Distance from the tip of the ignition elec-
trode to the bottom of the burner.
Dimension B = Distance from the tip of the ignition elec-
trode to the back edge of the burner.
Ionisation electrode
Ignition electrode
10. Assemble all other parts in the reverse order.
11. Test the entire unit to ensure that it is functioning
properly; make sure that all gas supply hoses are
impermeable using either a soap solution or a leak
detection spray.
12. Conduct an electrical safety test after performing
any maintenance work.
Unit
A
B
PGT 30 / 30 E
3 mm
15 mm
PGT 60 / 60 E
3 mm
15 mm
PGT 100 / 100 E
4 mm
30 mm
3. Loosen the clamping screw on the nozzle holder.
4. Loosen the clamping screw on the electrode holder.
5. Pull the ignition and ionisation electrodes out of the
electrode holder.
6. Remove the burner fastening screws and pull the
burner out of the unit.
7. Clean the burner using a steel brush and com-
pressed air.
8. Put the burner back into the unit and mount the igni-
tion and ionisation electrodes in the electrode
holder.
9. Adjust the ignition electrode in accordance with the
specifications below and tighten the fastening screw
on the electrode holder.
The tip of the ionisation electrode must be located
in the area of the flame.
Adjustments or maintenance work may only be
performed by authorised personnel
!
Proper Use
These devices have been designed and equipped exclu-
sively to be used for heating and ventilation for industrial
and commercial purposes.
The manufacturer is not liable for any damage resulting
from non-adherence to manufacturer specifications, le-
gal requirements or any modifications to the units.
An operation/use other than indicated in these in-
structions is prohibited!
In the case of non-compliance, we assume no li-
ability and our guarantee becomes null and void.
Service and Guarantee
For the guarantee to be valid, the customer must com-
pletely fill out the “guarantee certificate” enclosed with
all heating units and send it back to REMKO GmbH &
Co. KG in a timely manner after purchasing of the unit
and putting it into operation.
The units have undergone testing at the factory to ensure
proper functioning. If there are still malfunctions that
cannot be fixed by the operator using the troubleshoot-
ing instructions, please contact your dealer or contract
partner.
approx. dimensions
B