11
Series
PGT 30 / 30 E
PGT 60 / 60 E
PGT 100 / 100 E
Rated heat output
kW
26
55
100
Heating capacity
kW
10 – 26
25 – 55
50 – 100
Air output
m³/h
800
1.450
3.600
Fuel/type of gas
L i q u i d g a s C a t . I
3 B / P
,
I
3 +
Gas pressure
bar
1.5
1.5
1.5
Gas consumption
kg/h
0.78 – 2.0
1.95 – 4.27
3.9 – 7.8
Electrical connection 1~
V
230
230
230
Frequency
Hz
50
50
50
Power consumption max.
kW
0.07
0.11
0.125
Fuse protection
A
10
10
10
Type of protection
IP 44
IP 44
IP 44
Sound pressure level L
pA
1m
1)
dB(A)
56 – 69
62 – 72
74 – 82
Weight (without accessories)
kg
12
20
47
Dimensions total
length
mm
450
650
1060
width
mm
260
320
435
height
mm
410
510
620
1) noise measuring DIN 45635 - 01- KL 3
Technical Data
Operating current
230 V (-15 % + 10 %)
Frequency
50 Hz (40 - 60 Hz)
Safety period
5 seconds
Time to wait after unit switches off due to malfunction ca. 60 seconds
Permissible ambient temperature
– 20° C ... + 60 °C
Min. required ionisation current
5 µA
Sensitivity (ionisation current)
1 µA
Type of protection
IP 44
Technical Data Of The Burner Relay