Hot air distribution
hose extension
Hot air hose ø305
Attachment
Attachment
Hot air hose ø203
Hot air hose ø203
Hot air hose ø305
The unit is equipped with a high efficiency axial fan.
The high efficiency axial fan permits operation with hot
air hoses in different variants to transport the warmed
air exactly and efficiently to the specific place.
Please observe the following instructions when hot air
hoses are to be fitted:
◊ Please use exclusively those hot air hoses (acces-
sories) which have been approved by our company.
◊ The internal overlapping at the seams must to point
at air direction.
◊ Make sure that the hot air hoses are safely fastened
to the outgoing air connection piece.
◊ The pipes and hoses may not have sharp kinks and
bends in order to avoid heat accumulation.
◊ If the temperature at the blower aperture rises above
100° C the heating operation is stopped.
◊ A free air blow off must be ensured.
!
Due to the special high efficiency axial fan, the unit
should not be operated without hot air hoses.
Possible variations: (max. length 15 m)
Hot air hoses with ø 305
maximal 2x 7,6m
with hose extension
Hot air hoses with ø 203
maximal 2x 7,6m
with attachment
Hot air hoses ø 305 in combination with ø 203
maximal 1x 7,6m ø 305 plus 2x 7,6m ø 203
with attachment
REMKO
spare parts
:
Hot air hose ø305, 7,6m with sealing belt
EDV–No. 1099502
Hot air hose ø203, 7,6m with sealing belt
EDV–No. 1099501
Attachment with 2 outlets à ø203
EDV–No. 1099550
Hose extension ø305 with 2 sealing belts
EDV–No. 1009760