beautypg.com

Description of device, Starting, Safety instructions – REMKO ELT 18-S User Manual

Page 4

background image

4

Description of Device


The units are operating with electric energy. They are spe-
cially designed for the usage of hot air hoses and for a fully
automatic, all-purpose and simple application.
The units are equipped with capsuled electrical heating
elements, noiseless maintenance-free axial fans, safety
and after-cooling thermostat, thermostat socket and
connecting cable with plug.
The units are in accordance with the basic safety and
health requirements of the relevant EC – regulation.
The units are handled simply and are safe in operation.

Working of device

The units are equipped with a 4-stage operating switch.
In the first stage only the supply air fan is operated and
the units can be used for air circulation.
In the 2nd – 4th. stage the heating elements are acti-
vated and hot air is discharged.
The units can be operated with a room thermostat
(accessories) which is ready to be plugged in, to ensure
a constant room temperature. When the pre-selected
temperature has been reached, the thermostat stops
the heating operation to restart it when the temperature
has fallen below the set value.
When the units have been switched off by the operating
switch or the room thermostat, the supply air fan contin-
ues running for a certain time to cool down the heat ex-
changer, and then it stops automatically.

!

Connecting cable extensions may be laid exclu-
sively by authorized electricians based on the unit
capacity, cable length and taking the local terms of
use into account.

Starting


A well trained person is to be charged with the opera-
tion and control of the units.

2. Put operating switch into position "0".

3. Connect the unit-plug to an adequate

mains socket.

Safety Instructions


REMKO electric heaters will provide you with high utility
and long life thanks to our extensive material, function
and quality controls. Dangers may arise nevertheless if
the unit is used by persons not familiar with its opera-
tion or if the unit is not used for its intended purpose.

◊ The persons charged with the operation of the units

have to check these before starting work as to visible
defects of the operation and safety devices, as well as
to make sure that no protective devices are missing.
In the case of faults the supervisor is to be informed.

◊ In the case of faults which endanger the safe opera-

tion of the units, the units are to be stopped!

◊ During the operation of the units the applicable local

regulations are to be observed and the relevant
safety measures to be taken.

◊ Make sure that the prescribed safety distances from

combustible objects are observed!

◊ A free air suction and air blow off must be ensured.
◊ Never place foreign objects into the unit.
◊ Do not cover the units during operation.
◊ The units may not be operated near bath tubs,

showers, swimming pools, etc.

◊ The units may not be operated directly beneath a wall

socket.

◊ The units may not be exposed to direct water jets.
◊ Make sure that no water penetrates inside the units.
◊ The units may not be operated in rooms which are

endangered by explosions.

◊ Protect all electric cables outside the units from

damage (e.g. caused by animals).

!

The electric connection of the units is to be carried
out via a special supply point with fault current
safety switch.

1. Check the main voltage is in accordance with the

unit voltage.

Electrical connection 400 V 3 / N ~
Frequency 50 Hz
Fuse protection (required) 32 A (inert)

Application

◊ Drying of new buildings, spot heating of working places

outside or in fire-proof halls and production places.

◊ Permanent or temporary heating of rooms.
◊ Defrosting of machines vehicles and fire-proof storing

goods with keeping the prescribed distance of safety.

This manual is related to the following products: