beautypg.com

Installation – Desa VCM-50U User Manual

Page 14

background image

www.desatech.com

122274-01F

14

Figure 13 - Installing Gas Line and

Equipment Shutoff Valve (Model May

Vary From Illustration)

Gas Line Hole

Equipment
Shutoff Valves
(Install One)

INSTALLING GAS LINE

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.

IMPORTANT: See Connecting to Gas Supply
in your log set owner’s manual for details on
gas hookup.
You may run the gas line from either side of
the firebox (see Figure 13). Decide which side
you want to run the gas line from.
Note: This is one option for installing shutoff
valve. Check local codes for equipment shut-
off valve location requirements.

BRICK PANEL INSTALLATION

IMPORTANT: Installation of brick

should be done after the fire-

place is placed in a permanent

location.

The brick housings are already installed on
the panels. When installing brick housing
panels into fireplace, wear gloves as edges
may be sharp.
1. Beginning with left side panel, place

panel, bottom edge first, at an angle into
fireplace. Secure to bottom of fireplace
with screws provided.

2. Install right side as left side in step 1 using

screws provided.

3. Install back panel and secure back to

sides and bottom of firebox with screws
provided.

4. Using self-tapping screws and a drill, place

screws into large holes in back and side
panels (see Parts, page 32), through wire
mesh and into firebox wrapper to secure.

Figure 14 - Hole in Side Panel to Attach

to Firebox Wrapper

Hole in
Side Panel

Figure 15 - Installing Bricks into Brick

Housings

INsTAllATIoN

Continued

BRICK INSTALLATION

Each brick housing is stamped with a number
(full size bricks are not stamped). These num-
bers will help identify the brick when installing.
It is important to install these bricks exactly as
instructed. Press brick firmly into brick housing
until it snaps. Groove line on side of brick will
come in contact with flange on the brick hous-
ing. This secures brick into housing (see Figure
15). Smaller bricks may require a small portion
of furnace cement applied to back of brick to
secure it until grouting has been completed.
Bricks are packaged in separate boxes. The
brick matrixes on pages 15 through 27 show
how bricks are packaged and placed for each
size fireplace and the number of bricks per
box. There are 2 extra full bricks included in
Hearth Brick package.
Install bricks one section at a time starting with
hearth panel followed by the rear panel, left
panel and right panel. It is important to install
the bricks in sequence. Please note, full size
bricks are NOT stamped.