NOTIcE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• raise the mantel to an accept-
able height
• remove the mantel
bUILT-IN FIREbOx INSTALLATION
Built-in installation of this firebox involves
installing firebox into a framed-in enclosure.
This makes the front of firebox flush with wall.
If installing a mantel above the firebox, you
must follow the clearances shown in Figure
7, page 11. Follow these instructions to install
the firebox in this manner.
1. Frame in rough opening. The firebox fram-
ing should be constructed of 2 x 4 lumber
or heavier. Use dimensions and rough
opening layout in Figure 8. Adjust framing
so that firebox flushes with finished wall
surface. If installing in a corner, use dimen-
sions in Figure 9, for rough opening.
2. Install gas piping to firebox location. See
Installing Gas Line on page 14 and Con-
necting to Gas Supply in log set owner’s
manual.
3. Carefully set firebox in front of rough
opening with back of firebox inside wall
opening.
4. Carefully insert firebox into rough opening.
5. Attach firebox to wall studs using nails
or wood screws through holes in nailing
flange (see Figure 10).
6. Install and properly test gas log heater.
Follow installation instructions included
with the vent-free gas log heater that is
being installed.
IMPORTANT: When finishing your firebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc. may be butted up next to the sides and top
of the firebox. Combustible materials should
never overlap the firebox front facing.
WARNING: Do not allow any
combustible materials to overlap
the firebox front facing.
IMPORTANT: Noncombustible materials such
as brick, tile, etc. may overlap the front fac-
ing, but should never cover any necessary
openings.
WARNING: Do not allow non-
combustible materials to cover
any necessary openings.
INsTAllATIoN
Continued
Figure 10 - Attaching Firebox to Wall
Studs
Nailing
Flanges
Nails or
Wood
Screws
Figure 8 - Framing Dimensions
71" (50" Models)
100" (50" Models)
65" (42" Models)
92" (42" Models)
86.5" (36" Models)
61" (36" Models)
Maintain 1
1
/
2
"
Clearance at Sides
and Back of Fireplace
1
1
/
2
" Clearance
Not Required at
Nailing Flanges
Figure 9 - Corner Installation
30.125"
59.375" (50" Models)
54.625"
51.375" (42" Models)
45.375" (36" Models)
28.250"
(36" Models)