System configuration operation – REMKO KWL 130 H User Manual
Page 7

System configuration
Operation
The system can be easily operated
via the fully automatic iChiLL
controller. If due to local conditions
programming via the internal
control can only be realised with
difficulty, the system can also be
controlled via a cabled remote
control (accessory) or an external,
If the letter "A" is shown in
the display with a two-digit
numeric code, there is a fault
in the chiller. (see chapter on
trouble-shooting and customer
service).
!
CAUTION
The unit is designed as a 2 conduc-
tor system.
The system has 2 medium pipes
(conductors: supply and return)
for cooling using a cold medium
(KWL) or heating using a warm
medium (units with HP function
KWL...H).
In combination with a correspond-
ing system, the output can be
transmitted to the room to be
cooled via the floor, the building
structure or by means of ceiling
cooling.
For each of the different systems,
a minimum flow volume and
a minimum medium volume must
be ensured for the plant.
Chiller
System configuration
Medium intake
Medium outlet
Indoor area 1
Outdoor area
Indoor area 2
Indoor area 3
Room temperature control
Infrared remote control
Cabled remote control
Chilled water -
appliance
Chilled water -
appliance
Chilled water -
appliance
Condensate drain
Condensate line (only
units with HP-function)
Condensate drain
Condensate drain
Condensate collecting pipe
v
Methods of operation
Centralised
fault signal
iChiLL controller
Cable
remote control
Enabling contact
On/OFF Cooling/Heating
(e.g. building management
system)
(Standard equipment)
(Standard equipment)
(Accessories)
(Standard
equipment)
Help save on energy consump-
tion in stand-by mode! If the
device, system or component
is not in use, we recommend
disconnecting the power sup-
ply. Components with a safety
function is excluded from our
recommendation!
TIP
NOTE
The escape of refrigerant con-
tributes to climatic change. In
the event of escape, refrigerant
with a low greenhouse poten-
tial has a lesser impact on glo-
bal warming than those with a
high greenhouse potential.
This device contains refrige-
rant with a greenhouse poten-
tial of 1975. That means the
escape of 1 kg of this refrige-
rant has an effect on global
warming that is 1975 times
greater than 1 kg CO2, based
on 100 years. Do not conduct
any work on the refrigerant
circuit or dismantle the de-
vice - always enlist the help of
qualified experts.
potential-free, enabling contact
(standard).
A centralised fault contact, part of
the standard equipment, can be
used for the external signalling of
a fault.
7