2.

OPERATING DOMESTIC HOT WATER

2.0

Select only switch position (1).

2.1

Open hot water tap.

After about 3 seconds burner will always operate.

2.2

Temperature of domestic hot water can be varied

by adjusting the water flow rate at the tap.

Domestic thermostat (5) will control maximum

temperature leaving the appliance.

The knob can be set between minimum and maxi-

mum approximately 35 °C to 65 °C (95F to 1 49F).

For maximum temperature of domestic hot water

leave in maximum position.

3.

OPERATING HEATING & HOT WATER

TO SET AND ADJUST BUILT-IN TIMER MODEL

SEE OPPOSITE PAGE 3.

3.0

Select switch (2) position.

3.1

Switch on time clock, adjust room stat and/or

thermostatic radiator valves to high settings.

3.2

Burner will operate. Temperature output of

central heating can be adjusted by central

heating thermostat (4).

The knob can be set between minimum and

maximum approximately 40 °C to 85 °C (1 40F

to 1 85F).

While the appliance is being used to provide

domestic hot water, the central heating will not

operate.

When hot water is no longer required the

appliance will automatically revert to central hea-

ting and should not noticeably affect the level of

central heating.

Adjust external controls to required settings.

NOTE: An anti-cycling device is fitted to the

heating function.

When the boiler reaches its set maximum

temperature it will not operate on heating for

about 4 minutes but the domestic hot water func-

tion will always operate on demand.

3.3

TO SHUT DOWN THE APPLIANCE

3.3.1 For short periods, switch to only and turn

off all hot taps. For long periods switch of the on/

off switch (1).

If the appliance is to be shut down for long

periods when there is a risk of freezing, then

appliance should be drained.

Similar refilling must be done by a competent per-

son following approved procedures.

4.

CLEANING OF APPLIANCE OUTER CASING

4.1

Use a clean damp cloth.

Do not use any abrasive cleaners end with a dry

cloth lightly polish to protect painted surfaces.

Control panel and fixtures can be wiped with

damp cloth and dried. Spray polishes must not

be used on control panel surfaces or switches.

Care must be taken in preventing any liquids

entering the appliance.

4.2

CARE OF YOUR APPLIANCE AND SYSTEM

42.1

Annual servicing of your appliance is required to

maintain safety and efficiency of its operation.

Therefore it is recommended that the appliance

is serviced at least once a year and that the who-

le of the heating system be checked at the same

time by a qualified installer.

If it is known or suspected that a fault exists on

the boiler then it MUST NOT be used until the

fault has been corrected by a COMPETENT

PERSON.

It is essential that the instructions in this booklet

are strictly followed for safe and economic opera-

tion of the boiler.

SERVICING SHOULD BE CARRIED OUT BY A

QUALIFIED INSTALLER.