Precautions – Q3 Innovations AlcoHAWK ELITE User Manual

Page 9

background image

Error Message

Cause and Course Of Action

Sht

The user had a short exhale time during the test,

which likely means the user did not exhale steadily

and continuously for at least 5 seconds. Repeat

test.

reP

The unit is signifying to repeat the test because the

unit did not detect an even alcohol concentration

in the breath sample. This can occur if the user

varies the blowing force when performing a test or

if the Exhaust Port (see Components Diagram) is

obstructed. Repeat test.

H

The unit detected a very high alcohol concentration

(above 0.400% BAC).

Err

The sensor has been damaged and will need to be

returned for servicing. If this error message occurs

more than two consecutive times, please contact

Q3 Innovations for instructions to have your unit

serviced.

PRECAUTIONS

1. After drinking, smoking and eating, users should wait at least 20

minutes before testing.

2. Avoid testing in strong winds, in a closed room with a heavy amount

of smoke, or where alcohol is being consumed.

3. When the green light below PWR is blinking, replace the 9V alkaline

battery.

4. Do not blow cigarette smoke, food or liquid into the unit.
5. Only use the unit in a temperature range of 10 - 40°C or 50 - 104°F.