beautypg.com

DoorKing 6500 User Manual

Page 23

background image

21

1

Motor

2

Motor

3

Neutral

4

24V

A

C

5

Limit

6

Spare

7

Limit

8

COM

2.8 Auxiliary Terminal Description

2.9 Second Terminal Description

10

9

8

7

6

5

4

3

2

1

1. OPEN DIRECTION NON-CONTACT SENSOR (Photocell)

Stops gate movement in the open cycle. Gate resumes normal
operation when the input (obstruction) is cleared.

2. CLOSE DIRECTION NON-CONTACT SENSOR (Photocell)

Stops the gate in the closing cycle. Gate resumes closing when the
input (obstruction) is cleared.

3. Not used.

4. Not used.

5. COMMON.

6. COMMON.

1
2
3
4
5
6

This terminal is used to connect the secondary operator in a dual gate application.

Operator

Chassis

Ground

Interconnection Cable

1 Motor (Red)
2 Motor (Blue)
3 Neutral (White)
4 24VAC (Purple)
5 Limit (Yellow)
6 Spare (Brown)
7 Limit (Orange)
8 COM (Gray)

6500-065-K-7-08