Connecting cash drawer (optional) – Posiflex TX-4200 User Manual
Page 9
Page 9
M: 1x Power USB 24V
N: 1x USB
O: 1x PS/2
In TX series system, COM1, 2, 3 and 4 can supply a +5 V DC through system
BIOS, COM 5 &6 +5V/+12V are supported by jumper setting. The VGA port
can support +12 V power through system BIOS setting for Posiflex LCD
display monitor. 2
nd
VGA port +12V power is set by jumper. Nevertheless,
except Posiflex peripheral device, do not connect any other device to this
port before the power in this port is disabled.
CAUTION:
Please turn off the system power first! Then hold the base and
move the terminal carefully.
Connecting Cables
To have the terminal ready for operation, please connect all required cables to
the appropriate connectors. Please make sure that each connector is connected
to the correct port with the correct orientation. Damages due to incorrect
connection or orientation are not covered by product warranty!
Some connectors like the COM port or LAN port or CR connector have
to be gently inserted until a click is heard. It is recommended that connectors
such as the COM port and VGA connector be screwed into place once
seated. Please make sure that each connector has to be connected to the right
device in the right way.
CAUTION: On doing any insertion or extraction of any connector, please
always hold the connector head itself instead of pulling on the
cable wire. Failure to do this could damage the cable and jack
that is considered as an artificial destruction and is not
covered by the warranty.
Connecting Cash Drawer (Optional)
The RJ45 connector in I/O area of a TX-4200/4200E system can be used for
controlling most of the common cash drawers which are driven by +12V signal.
However, it is most recommended to use Posiflex CR-2000 or CR-2200 or
CR-3100 or CR-3200 or CR-4000 or CR-4100 or CR-4210 or CR-6310 for