INSTALLATION INSTRUCTIONS

Electrical

Insulation Blankets

In general, insulation blankets for external use

on gas water heaters are

not necessary. The

purpose of an insulation blanket is to reduce the

standby heat loss from the water heater’s storage

tank. Since these water heaters do not store water,

they eliminate the need for the insulation blanket.

WARNINGS:

If local codes require the application of external

insulation blanket kits, carefully follow the

manufacturer’s installation instructions included

with the kit. Only use blanket kits that are

approved for use with your water heater.

NEVER cover the air inlet, flue outlet, or

operating and warning labels attached to the

water heater. Operating and warning labels

should not be relocated to the exterior of an

insulation blanket. Covering these components

will cause dangerous operating conditions that

can lead to death, personal injury, property

damage, and/or product damage.

The manufacturer’s warranty does not cover any

damage or defect caused by insulation, insulation

attachment, or use of any type of energy-saving

or other unapproved devices (unless authorized

by the manufacturer). The use of unauthorized

energy-saving devices can result in death,

personal injury, and/or property damage. The

manufacturer disclaims any responsibility for

such loss or injury resulting from the use of such

unauthorized devices.

Installation Precautions

Follow all installation instructions covered in this

manual.

Check the inlet gas pressure to make sure it is

within the range specified on the rating plate.

Make sure there is adequate air for combustion

and ventilation as described on pages 37–38 or

page 44 in this manual.

Maintain proper clearances to combustibles and

noncombustibles as specified on the rating plate.

Make sure the venting system complies with

local codes, National Fuel Gas Codes (ANSI

Z223.1/NFPA 54) or CSA B149.1, and the

guidelines found on pages 34 through 46 in this

manual.

Contact the local gas company to make sure the

gas meter and gas piping are adequately sized.

Use only Teflon tape on all male water line

connections and fittings.

• Do not block or restrict any air intake openings.
• Do not remove the front cover unless absolutely

necessary. This should only be done by a

qualified service technician.

• Do not install this product where standing water

may occur.

• Do not use pipe dope on water line connections

and fittings.