beautypg.com

Installation instructions, Warning, Notices – Paloma PHH-32 part 2 User Manual

Page 23: Notice, Electrical, Remote control installation

background image

59

INSTALLATION INSTRUCTIONS

Electrical

Remote Control Installation

WARNING:

Field wiring connections

and electrical grounding must comply with local

codes or, in the absence of local codes, with the

latest edition of the National Electrical Code, ANSI/

NFPA 70, in the U.S., or Canadian Electrical Code,

CSA C22.1, Part 1, in Canada.

NOTICES:

Remote control cable can be any Type–T 18

AWG wire similar to a thermostat wire and need

not be polarity-sensitive.

It is not recommended to have wiring exposed.
• Do not apply sealant to remote control cable.
• Do not use network cable, telephone wire, or

any twisted-pair cable.

Connecting the MAIN (UMC-117) Remote

Control to a Wall:

Drill a 1- to 1 1/2-in. (2.5/3.8-cm) hole at the

proposed control location. Install the remote

control cable between the location of the

remote control and the water heater.

Remove the remote control from the base plate.

Feed the remote control cable through the large

center hole in the base plate.

Install the base plate to the wall using suitable

screws and wall anchors.

NOTICE:

The tabs on the base plate

should always point out.

Connect the remote control to the remote

control cable.

Position the remote control on the base plate.

NOTICE:

The tabs on the base plate

should line up with the slots on the back of the

control panel.

Secure the control panel to the base plate with

one screw into the bottom tab.

NOTICE:

Do not attempt to connect the

remote control or control wire to the water heater

while the water heater has power applied to it.

Damage to the water heater will occur. Do not

cut or strip the wiring while it is connected to the

water heater or while the water heater has power

applied to it.