Osburn OB02401 User Manual
Page 16

16
2.8 Connector installation
A masonry flue connector may provide acceptable performance (Figure 2.8a); however, we 
recommend the use of a chimney liner (rigid or flexible) to ensure satisfactory performance 
(Figure 2.8b). To ensure an optimal draft, we also strongly recommend adding a minimum of 
18” rigid liner between the roof flashing and the rain cap. Slip connectors for continuous liners 
should also be installed. Use Listed Chimney Liners – UL1777, CAN/ULC-S635. 
Figure 2.8a
Figure 2.8b
 
ATTENTION INSTALLER: When positioning the unit in a fireplace opening prior to the flue 
installation, install the insert into the opening until the top lip of air jacket is flush with fireplace 
facing. 
 
If lag-bolts and anchors are to be used to secure the insert, the whole locations should be 
marked with the unit in place. Remove the insert and locate the anchors. 