Osburn OB02401 User Manual
Page 13

13
 
The more extended the insert, the greater the heat transfer to the room. When installed as an 
extended insert, the front edge of the air jacket will be installed flush with the fireplace facing. 
Otherwise the unit can be moved back as much as 3 3/4" (95 mm) or any position in between. 
The position chosen will depend on your own preference for most installations, your current 
configuration, the compliance with the preceding installation instructions and compliance with the 
building code requirements. To determine the minimum and maximum protrusion of the insert, 
refer to table Data for floor protection calculation. 
 
Data for floor protection calculation
MAXIMUM 
EXTENDED
A
B
(Note 1)
C
E
AIR JACKET
Smaller
than 6 ft
2
*
Bigger or
= to 6 ft
2
*
INCHES
16"
20"
CAN: 18" 
USA: 16" 
7"
8 1/2"
Flush with 
fireplace 
facing 
MILLIMETRES
406 mm
508 
mm 
CAN: 457 mm
USA: 406 mm
178 mm
216 mm
MINIMUM 
EXTENDED 
A
B
(Note 1)
C
E
AIR JACKET
Smaller
than 6 ft
2
*
Bigger or
= to 6 ft
2
*
INCHES
16"
20"
CAN: 18" 
USA: 16" 
3 1/4"
12 1/4"
Back from 
fireplace 
facing 3 3/4" 
MILLIMETRES
406 mm
508 
mm 
CAN: 457 mm
USA: 406 mm
83 mm
311 mm
*Refers to masonry fireplace opening.
