beautypg.com

Dc powering and indicators – Olson Technology OLMR User Manual

Page 6

background image

Figure 1 - Dimensioned Unit

DC POWERING AND INDICATORS

The unit operates with the OTPS-12A AC/DC power supply. The typical current requirements
for the receiver with that power supply is 150mA. The current draw for other voltages is as
follows:

Input Voltage

10V

DC

12V

DC

15V

DC

Rx Current

200mA 150mA 120mA

An LED indicator is provided for easy setup and maintenance. The tri-color indicator LED is
yellow when the optical input is too low, red when the optical input is too high and is green
when the optical input is in the usable range. This range is approximately -15dBm to +3dBm.
for the PIN detector style receiver. The levels vary widely with the APD option receivers.

025-000565 Rev. X9

www.olsontech.com