Safety warnings, High voltage, Fire hazard – Olson Technology LP-CH-16B User Manual
Page 3: Shipping alert, System overview
025-370403 REV X9
Page 3 of 11
SAFETY WARNINGS
LASER RADIATION
The laser transmitters emit invisible radiation that can cause permanent eye
damage. AVOID DIRECT EXPOSURE TO BEAM. Operate only with
the proper optical fiber installed in the transmitter optical connector. The laser
transmitter should be disabled with the front panel switch whenever the optical
connector is empty.
HIGH VOLTAGE
The AC input power supply contains no user serviceable parts. There is exposed high voltage inside the
supply. The power supply housing should be opened only by factory service technicians.
FIRE HAZARD
The AC input rear power supply fuse is a 3AG, 3.25A, slow blow fuse. To avoid a risk of fire, this fuse
should be replaced only with an identically rated fuse.
SHIPPING ALERT
The main chassis is not intended as a shipping container. Shipping the system with any module installed can
cause severe physical damage.
SYSTEM OVERVIEW
DESCRIPTION MODEL PART NUMBER
MAIN CHASSIS
LP-CH
037-000403
95-240VAC POWER SUPPLY
LP-PS
037-000406
48VDC POWER SUPPLY
LP-PS-48
037-000451
LASER TX MODULE 6dBm
LP-OT-6
037-000400
LASER TX MODULE 8dBm
LP-OT-8
037-080433
LASER TX MODULE 9dBm
LP-OT-9
037-090433
LASER TX MODULE 10dBm
LP-OT-10
037-100433
LASER TX MODULE 12dBm
LP-OT-12
037-120433
LASER TX MODULE 14dBm
LP-OT-14
037-140433
LASER TX MODULE 15dBm
LP-OT-15
037-150433
TRIPLE RX MODULE
LP-OR-300
037-000401
RSM 1&3 w/o OPTICAL RX
LP-DC-212-NR
037-000454
RSM 1&3 w/ OPTICAL RX
LP-DC-212
037-000447
RSM 2&4 (req. LP-DC-212)
LP-DC-234
037-000448
SNMP STATUS INTERFACE
LP-SNMP
037-000461
MODULE EXTRACTOR
LP-EX
010-000930
A system can have a single power supply or 2 redundant supplies. With a single power supply, a fully populated
system holds 15 RF/optical modules. With dual power supplies, a fully populated system holds 14 RF/optical modules.
All modules can be hot swapped.