beautypg.com

Olson Technology FRMUC-AR440 User Manual

Page 4

background image

025-000477 REV x1

Page 4

The Arris 400 Gemini node used in this installation proceedure may differ in configuration, adjustments
to the install proceedure may required.

Step 1: Loosen the 5 captive screws holding on the metal cover underneath the metal tray. (See Figure 1)

Step 2: Remove the cover plate.
Step 3: Locate TX “A” IN and TX “B” IN port (See Figure 2). Remove the two Standard SMB cables from these
ports. Zip tie the two cables to the power supply cables to keep them out of the way (Figure 3). Then plug in the
Standard SMB cable which is supplied with the kit, at SWITCHED IN. (See Figure 4). Then place the metal cover
back into postion. Be sure to not pinch any fiber optic cable that may be in the way.

NOTE: The FRMUC-AR440 kit uses 75

type SMB connections on the RF cables. These connections

(and those they mate with) can be damaged if inadvertantly abused. Use caution in handling and plugging/
unplugging these. Always press them straight in and pull them straight out.

Figure 1:

Figure 2:

Figure 3:

Figure 4: