beautypg.com

2 physical specifications, 3 environmental specifications – Northern Airborne Technology ACP51-100 User Manual

Page 7

background image

ACP51-100 DACS Audio Control Panel

SM81 Installation and Operation Manual


Section 1 Rev: 1.00

Issue 1

Page 1-3

ENG-FORM: 800-0114.DOT

CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.

Output Signals

ISO Mode

When the Patient switch on the front panel of the ACP51 is placed in the NORM position,
the ISO Mode output is inactive. When the Patient switch on the front panel of the ACP51
is placed in the ISO position, the ISO Mode output is active (grounded).
Quantity: one
Logic:

active LO, switched ground

Output Inactive:

>10 M

Ω

Output Active:

≤2

Ω

Current:

100 mA maximum

Bidirectional Signals

Communication

The ACP51 communicates with an external communications management system such as
the AMU50 via one bi-directional RS422 serial data port.

1.4.2

Physical Specifications

Height

57.15 mm (2.25 in) maximum

Depth

68.07 mm (2.68 in) maximum behind Dzus rail

Width

146.05 mm (5.75 in) maximum

Weight

0.51 kg (1.12 lbs) maximum

Material and Finish

Brushed aluminum, conversion coated

Connectors

One 15 pin D-Sub (male), V5 locking hardware

Installation

RS-422 Cable: 20.0 m (785.9 in) maximum

Installation Kit: ACP50-IKC

Mounting

Four Dzus fasteners, 2.89 cm (1.137 in) vertical spacing

1.4.3

Environmental Specifications


The ACP51-100 has been tested to the environmental conditions listed below. Environmental categories
for which TSO compliance has been demonstrated are listed on the Environmental Qualification Form in
Section 2 of this manual.

Temperature

-40 to +70

° C (operating)

-45 and +85

° C (short-time operating)

-55 to +85

° C (ground survival)

Altitude

50,000 feet max

Humidity 95%

non-condensing

Shock

Operational shock;

6 g for 11 ms

Crash safety (impulse); 20 g for 11 ms

Crash safety (sustained); 20 g for 3 s

Vibration RTCA/DO-160E Section 8 Categories (SBM) (U2FF1)