2 physical specifications, 3 environmental specifications – Northern Airborne Technology ACP53-001 User Manual
Page 7
ACP53-001 DACS Audio Control Panel
SM75 Installation and Operation Manual
Section 1 Rev: 1.02
Issue 1
Page 1-3
ENG-FORM: 800-0115.DOT
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.
Output Signals
NORM Mode, BACKUP Mode
The ACP53 provides two outputs for mode control of an external communications
management unit such as the AMU50.
Bidirectional Signals
Communication
The ACP53 communicates with an external communications management system such as
the AMU50 via one bi-directional RS422 serial data port.
1.4.2
Physical Specifications
Height
76.70 mm (3.02 in) maximum
Depth
68.07 mm (2.68 in) maximum behind Dzus rail
Width
146.56 mm (5.77 in) maximum
Weight
0.65 kg (1.42 lbs) maximum
Material and Finish
Brushed aluminium, conversion coated
Connectors
One 15 pin D-Sub (male), V5 locking hardware
Installation
RS-422 Cable: 20.0 m (785.9 in) maximum
Installation Kit: ACP50-IKC
Mounting
Four Dzus fasteners, 4.76 cm (1.875 in) vertical spacing
1.4.3
Environmental Specifications
The ACP53-001 has been tested to the environmental conditions listed below. Environmental categories
for which TSO compliance has been demonstrated are listed on the Environmental Qualification Form in
Section 2 of this manual.
Temperature
-40 to +70
° C (operating)
-45 and +85
° C (short-time operating)
-55 to +85
° C (ground survival)
Altitude
50,000 feet max
Humidity 95%
non-condensing
Shock
Operational shock;
6 g for 11 ms
Crash safety (impulse); 20 g for 11 ms
Crash safety (sustained); 20 g for 3 s
Vibration RTCA/DO-160E Section 8 Categories (SBM) (U2FF1)