Northern Airborne Technology ACP53-001 User Manual
Page 18
ACP53-001
Environmental Qualification Form
Rev: 1.00
Nov 27, 2008
Page 2 of 3
ENG-FORM: 521-0102.DOT
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.
Conditions
Section
Description of Conducted Tests
Explosive Atmosphere
9.0
Category X, no test performed.
Waterproofness
10.0
Category X, no test performed.
Fluids Susceptibility
11.0
Category X, no test performed.
Sand and Dust
12.0
Category X, no test performed.
Fungus
13.0
Category X, no test performed.
Salt Fog
14.0
Category X, no test performed.
Magnetic Effect
15.0
Category Z.
Power input
16.0
Category Z.
• Equipment receives conditioned input power
from AMU50-xxx. The equipment was tested
configured as part of the DACS.
• The system was tested to DO-160E
subparagraph 16.6.1.3 b, requirement for
equipment with digital circuits.
• The system was tested to DO-160E
subparagraph 16.6.1.1 b (3) Emergency
Operating Voltage conditions.
• The system was tested to DO-160E
subparagraph 16.6.2.2 Low Voltage
Conditions
Voltage Spike
17.0
Category A.
• Equipment receives conditioned input power
from AMU50-xxx. The equipment was tested
configured as part of the DACS.
Audio Frequency Susceptibility
18.0
Category Z.
• Equipment receives conditioned input power
from AMU50-xxx. The equipment was tested
configured as part of the DACS.
Induced Signal Susceptibility
19.0
Category [ZC].