2.4

Installation Procedures

2.4.1

Warnings

WARNING:

High volume settings can cause hearing damage.

Set the headset volume control to the minimum volume setting prior to

conducting tests, and slowly increase the headset volume to a

comfortable listening level.

2.4.2

Cautions

CAUTION:

Never ground any output line from the AA22 or permanent damage may

result. Use of a fully floating audio wattmeter or transformer-coupled meter is

recommended. Always check ADF and compass calibration after installing

external speakers or "PA" amplifiers. Significant single cycle errors may be

caused by the concentration of steel and magnetic material.

2.4.3

Cabling and Wiring

All wire shall be selected in accordance with the original aircraft manufacturer's Maintenance Instructions
or AC43.13-1B Change 1, Paragraphs 11-76 through 11-78. Unshielded wire types shall qualify to
MIL-W-22759 as specified in AC43.13-1B Change 1, Paragraphs 11-85, 11-86, and listed in Table 11-11.
For shielded wire applications, use Tefzel MIL-C-27500 shielded wire with solder sleeves (for shield
terminations) to make the most compact and easily terminated interconnect. Follow the connector map in

Section 2.7 as required.

Allow 3" from the end of the shielded wiring to the shield termination to allow the connector hood to be
easily installed. Reference the interconnect drawing in Section 2.7 for shield termination details. Note that
the hood is a "clamshell" hood, and is installed after the wiring is complete.

Aircraft harnessing shall

permit the unit to be lowered from the panel for easy access to all side adjustments. Do NOT mount the
unit until all adjustments have been performed.

Maintain wire segregation and route wiring in accordance with the original aircraft manufacturers
Maintenance Instructions.

Unless otherwise noted, all wiring shall be a minimum of 22 AWG, except power and ground lines, which
shall be a minimum of 20 AWG. Reference the Interconnect drawing for additional specifications.

Check

that the ground connection is clean and well secured, and that it shares no path with any electrically noisy
aircraft accessories such as blowers, turn and bank instruments or similar loads. Power to this unit must
be supplied from a separate circuit breaker or fuse (fast blow), and not attached to any other circuit
breaker without additional protection. Verify that the selected circuit breaker size and wire gauge are
adequate for the installation using the techniques specified in AC43.13-1B Change 1, Paragraphs 11-47
through 11-51 and 11-66 through 11-69.