Remote Mounting of the Blower Pack with RH Series
7. Remove the front cover from the humidifier.
8. Install the steam line as per the RH Series installation manual.
Note: Maximum recommended length of steam line is: 8 ft. for 5lbs/hr, 15 ft. for 10lbs/hr.
9. Put the power leads from the blower pack through knock out at the bottom right of the unit.
10. Connect the power leads for the blower pack to the terminal 19 and 20 on the RH Series’
control terminal strip.
Note: Improper wiring could damage the blower pack or the RH Series PCB.
11. Replace the front cover on the humidifier.
12. Once the power is restored, the RH Series humidifier is ready for use.
Remote Mounting of the Blower Pack with the ResDelux
The Blower Pack can be combined with the previous residential humidifier model, the ResDelux.
The Blower Pack Kit contains a supplementary set of cables to link the Blower Pack to the
humidifier. To properly mate the new Blower Pack with the ResDelux humidifier, follow these
steps:
1. Open up Blower Pack.
2. Replace with supplementary wire harness provided.
3. Hookup is described in ResDelux manual.
4. Run new wire harness in same location as previous wire.
5. Close Blower Pack.
Note: If more length between humidifier and Blower Pack is required, extend the harness by
adding additional wire (by others). Suitable wire is 18 AWG.