Niveo Professional NMC1012R User Manual
Page 2

DIP Switch Setting
V. Link Fault Pass-through (LFP)Function
When LFP function is enabled, the device of
either TP port or fiber port is loose or link, link
status on TP port will inform the fiber port of the
same device and vice versa. If the TP port is
unplugged, the converter stops transmitting
over the fiber port, causing the remote fiber
node link to fail. The LED will show link failure
on both the TP and fiber ports. If the fiber link
fails, the converter causes the remote TP node
link to fail. The LED also shows the link failure
on both the TP and fiber ports. The figures
below show normal status when the link
succeeds and the error status when TP cable A
/ D or fiber cable B/C fails to connect.
Note:
Warning :
When the setting of the DIP switch is changed, the
power has to be turned off and the new setting will be
effective after turned on again.
Technical Specifications
Standards
IEEE 802.3ab 10BaseT
IEEE 802.3u 100BaseTX
IEEE 802.3z 1000BaseSX
IEEE 802.3x Flow Control
Features
Number of Ports:
1 10/100/1000BaseT with
RJ-45 Connector
1 1000BaseSX with Fiber
Connector (Multi/Single Mode,
SC Connector)
Data Transfer Rate
2000Mbps/Full-Duplex
Transmission
Media
TP: 10/100/1000BaseT Cat. 5,
5E, 6 UTP/STP, up to 100 m
1000BaseSX:
6
2.5/125μm Multi Mode Fiber
optic cable, up to 220 m
50/125μm Multi Mode Fiber
optic cable, up to 550 m
LED Indicators
Per Port:
(TX): Link, TX
(FX): Link, RX
Per Unit: Power
Power
Requirement
DC5V/2A
Power
Consumption
10 Watts (Max)
Dimensions
102 x 74 x 22 mm (L x W x H)
Weight
240 g
Operating
Temperature
0 to 40℃
Storage
Temperature
-20 to 90℃
Humidity
10 to 90% RH
(non-condensing)
Certifications
FCC Class B, CE