beautypg.com

Niveo Professional NMC1012R User Manual

Page 2

background image





DIP Switch Setting


V. Link Fault Pass-through (LFP)Function

When LFP function is enabled, the device of
either TP port or fiber port is loose or link, link
status on TP port will inform the fiber port of the
same device and vice versa. If the TP port is
unplugged, the converter stops transmitting
over the fiber port, causing the remote fiber
node link to fail. The LED will show link failure
on both the TP and fiber ports. If the fiber link
fails, the converter causes the remote TP node
link to fail. The LED also shows the link failure
on both the TP and fiber ports. The figures
below show normal status when the link
succeeds and the error status when TP cable A
/ D or fiber cable B/C fails to connect.


Note:



Warning :

When the setting of the DIP switch is changed, the

power has to be turned off and the new setting will be
effective after turned on again.

Technical Specifications

Standards

IEEE 802.3ab 10BaseT
IEEE 802.3u 100BaseTX
IEEE 802.3z 1000BaseSX
IEEE 802.3x Flow Control

Features

Number of Ports:
1 10/100/1000BaseT with
RJ-45 Connector
1 1000BaseSX with Fiber
Connector (Multi/Single Mode,
SC Connector)

Data Transfer Rate

2000Mbps/Full-Duplex

Transmission
Media

TP: 10/100/1000BaseT Cat. 5,
5E, 6 UTP/STP, up to 100 m
1000BaseSX:
6

2.5/125μm Multi Mode Fiber

optic cable, up to 220 m
50/125μm Multi Mode Fiber
optic cable, up to 550 m

LED Indicators

Per Port:
(TX): Link, TX
(FX): Link, RX
Per Unit: Power

Power
Requirement

DC5V/2A

Power
Consumption

10 Watts (Max)

Dimensions

102 x 74 x 22 mm (L x W x H)

Weight

240 g

Operating
Temperature

0 to 40℃

Storage
Temperature

-20 to 90℃

Humidity

10 to 90% RH
(non-condensing)

Certifications

FCC Class B, CE






This manual is related to the following products: