Switch, Function, Comment – Nevion ADC-SDI User Manual
Page 12: Manual mode on/off, When on, enables switches 2, 3, 4, and 5, Input channel select 1, According to table 3, Input channel select 2, Edh disable on/off, Mark field 1 disable on/off
![background image](https://www.manualsdir.com/files/799663/content/doc012.png)
ADC-SDI
Rev.
6
Switch #
Function
Comment
1
Manual mode on/off
When on, enables switches 2, 3, 4, and 5
2
Input Channel select 1
According to Table 3
3
Input Channel select 2
According to Table 3
4
EDH disable on/off
When on, the EDH will not be inserted into the
SDI-output.
5
Mark Field 1 disable on/off
When on, the Mark Field 1-feature is not used.
6
Luma/chroma separation filters According to Table 4
7
Luma/chroma separation filters According to Table 4
8
Factory Reset on/off
To restore internal EEPROM only
9
Chroma blanking for Teletext
Chroma blanking for Teletext within vertical
blanking area
10
Running mode on/off
For factory use only
Table 2: Summary of the DIP switches. Switch 9 and 10 are mainly for factory use, while
switches 1, 2, 3, 4, 5, 6 and 7 will be used when no GYDA controller is available.
5.2.1 Switch 1 - Manual mode
Switch 1 is the manual mode switch. If set to on, the ADC-SDI is primarily assumed to be
operated with switches alone. If set to off, the ADC-SDI is assumed to be used with a GYDA
controller.
Factory setting is switch 1 in off position.
With switch 1 off
While in automatic mode, switches 2, 3, 4 and 5 are without any effect.
With switch 1 on
In manual mode, the functionality of switches 2, 3, 4 and 5 is as follows:
5.2.2 Switches 2 and 3
These two switches determine the input channel selection. See Table 4.
Factory setting is switch 2 and switch 3 off.
Sw #3
Sw #2
Input Channel Select
Comment
0
0
Automatic
Search for any possible input type.
0
1
CVBS Ch. 1
Only search for CVBS on Ch. 1
1
0
CVBS Ch. 2
Only search for CVBS on Ch. 2
1
1
S-Video
Only search for S-Video; Luma Ch. 1 and
Chroma Ch. 2
Table 3: Manual selection of video mode
5.2.3 Switch 4
Switch 4 turns on/off disabling of EDH in the output SDI. With switch 4 off, the EDH is
included in the SDI signal, with switch 4 on, EDH is not included.
Factory setting is switch 4 in off position.
5.2.4 Switch 5
Switch 5 turns on/off disabling of the Mark Field 1-feature. With switch 5 off the Mark Field 1-
feature is enabled, with switch 5 on the Mark Field 1-feature is disabled.
Factory setting is switch 5 in off position.
network-electronics.com
|
12