beautypg.com

Switch, Function, Comment – Nevion ADC-SDI User Manual

Page 12: Manual mode on/off, When on, enables switches 2, 3, 4, and 5, Input channel select 1, According to table 3, Input channel select 2, Edh disable on/off, Mark field 1 disable on/off

background image

ADC-SDI

Rev.

6

Switch #

Function

Comment

1

Manual mode on/off

When on, enables switches 2, 3, 4, and 5

2

Input Channel select 1

According to Table 3

3

Input Channel select 2

According to Table 3

4

EDH disable on/off

When on, the EDH will not be inserted into the
SDI-output.

5

Mark Field 1 disable on/off

When on, the Mark Field 1-feature is not used.

6

Luma/chroma separation filters According to Table 4

7

Luma/chroma separation filters According to Table 4

8

Factory Reset on/off

To restore internal EEPROM only

9

Chroma blanking for Teletext

Chroma blanking for Teletext within vertical
blanking area

10

Running mode on/off

For factory use only

Table 2: Summary of the DIP switches. Switch 9 and 10 are mainly for factory use, while

switches 1, 2, 3, 4, 5, 6 and 7 will be used when no GYDA controller is available.

5.2.1 Switch 1 - Manual mode

Switch 1 is the manual mode switch. If set to on, the ADC-SDI is primarily assumed to be
operated with switches alone. If set to off, the ADC-SDI is assumed to be used with a GYDA
controller.

Factory setting is switch 1 in off position.

With switch 1 off

While in automatic mode, switches 2, 3, 4 and 5 are without any effect.

With switch 1 on

In manual mode, the functionality of switches 2, 3, 4 and 5 is as follows:

5.2.2 Switches 2 and 3

These two switches determine the input channel selection. See Table 4.

Factory setting is switch 2 and switch 3 off.

Sw #3

Sw #2

Input Channel Select

Comment

0

0

Automatic

Search for any possible input type.

0

1

CVBS Ch. 1

Only search for CVBS on Ch. 1

1

0

CVBS Ch. 2

Only search for CVBS on Ch. 2

1

1

S-Video

Only search for S-Video; Luma Ch. 1 and
Chroma Ch. 2

Table 3: Manual selection of video mode

5.2.3 Switch 4

Switch 4 turns on/off disabling of EDH in the output SDI. With switch 4 off, the EDH is
included in the SDI signal, with switch 4 on, EDH is not included.

Factory setting is switch 4 in off position.

5.2.4 Switch 5

Switch 5 turns on/off disabling of the Mark Field 1-feature. With switch 5 off the Mark Field 1-
feature is enabled, with switch 5 on the Mark Field 1-feature is disabled.

Factory setting is switch 5 in off position.


network-electronics.com

|