3 configuration – Nevion ADP-3GHD User Manual
Page 6

ADP-3GHD
Rev. A
nevion.com | 6
3 Configuration
The ADP-3GHD supports a number of different formats. The correct configuration can either
be set with a DIP switch or with the GYDA system controller. The layout of ADP-3GHD is
shown in the drawing below.
Figure 2 - ADP-3GHD module layout
DIP switch configuration must be set according to the table below:
Switch
#
Label Function DIP=OFF
Function DIP=ON
Comment
1
RED
Independent rings
Redundant ring
Card can work on
either two independent
rings or one ring with
redundant
paths/directions.
Redundant mode
implies CHO function
on DROP outputs.
2
R1
Pass primary ring
Add to primary ring
Chooses which signal
goes to the OUT port of
the primary ring
3
R1
Drop from primary ring
No drop from primary
ring
Enable DROP output
for the primary ring.
4
R2
Pass secondary ring
Add to secondary ring Only in use when
switch #1 set OFF
5
R2
Drop from secondary ring No drop from
secondary ring
Only in use when
switch #1 set OFF
6
RCL
Reclocker Bypass
Reclocker ON
Reclocker mode
7
EQ
Cable equalizer Bypass
(Loss of signal will not
work on this mode)
Cable Equalizer ON
Equalizer mode
8
OVR
Module controlled by
Gyda system controller
Module controlled by
DIP switches
Select GYDA config.
Mode
Table 1: ADP-3GHD DIP switches
All DIP switches are off when pointing towards the release handle.
DIP switches