4 configuration, 1 stand alone mode, 2 multicon gyda mode – Nevion FC-3G-EO-14 User Manual
Page 16: 1 address setting
FC-3G-EO/OE-14/28
Rev. C
nevion.com | 16
4 Configuration
Flashlink Compact can operate in two modes. Stand alone and Multicon Gyda
controlled mode. This setting is set by switch 8 on the front of the Flashlink Compact.
If Flashlink Compact does not appear in Multicon Gyda, check that switch 8
is set to on.
4.1 Stand alone mode
The Flashlink Compact is configured to transport SD/HD/3G-SDI with reclocked set to
auto.
Switch 1 to 7 has no function in this mode.
4.2 Multicon Gyda mode
In this mode configuration and monitoring can be done by Multicon Gyda. This function
also has to be unlocked by the Multicon Gyda options sold separately. See chapter 6
Unlocking options
The Flashlink Compact can be seen as a two slot Flashlink frame populated with 14
OE or 14 EO converters. Each slot must be set to a unique sub-rack and slot address.
This is done with switch 1 to 7 on the front of the product.
In order to ensure proper operation of the system, it is important that no
sub-racks or Flashlink Compact controlled by the same Multicon Gyda have
the same address set.
4.2.1 Address setting
For communication with Multicon Gyda the addresses on the Flashlink Compact has to
be set. Depending on the product one or two unique address has to be set. This is
done by the switches in front of the product.
The first 3 switches set the sub-rack address:
SW1
SW2
SW3
Sub-rack
OFF
OFF
OFF
0
ON
OFF
OFF
1
OFF
ON
OFF
2
ON
ON
OFF
3
OFF
OFF
ON
4
ON
OFF
ON
5
OFF
ON
ON
6
ON
ON
ON
7