6 RS422 commands

This card uses the FLP 4.0 protocol to be configured and monitored. See separate
documents for definition of this protocol.

6.1 FLP4.0 block commands

Common FLP4.0 block for both single and dual converter is listed below.

6.1.1 CEQ 0

Electrical input 1.

::= 'ceq'
::= ['cd'|'ncd'] ['bypass'|'mute']

::= 'enable'|'bypass'|'mute'

6.1.2 CEQ 1

Electrical input 2.

::= 'ceq'
::= ['cd'|'ncd'] ['bypass'|'mute']

::= 'enable'|'bypass'|'mute'

6.1.3 TEMP 0

Board temperature.

::= 'temp'
::= ['alarm'] ['C'] ['ulim' ]

['llim' ]

::= |
::= 'ulim'
::= 'llim'

6.1.4 PWR 0

::= 'pwr'
::= ['Vnom'] []

6.1.5 PWR 1

::= 'pwr'
::= ['Vnom'] []

6.1.6 LSR 0

Optical output 1.

::= 'lsr'
::= ['T'|'C'|'D'] ['nm'] ['dBm']

['on'|'off'] ['fail']

::= |||
::= 'on'|'off'
::= 'type' 'T'|'C'
::= 'lambda'
::= 'lpwr'