beautypg.com

MultiDyne SMPTE-HUT User Manual

Page 9

background image

SMPTE HUT Manual

10/15/2014

Multidyne Electronics Inc.

9

To avoid having to set the Ikegami CCUs for single fiber mode, you can configure the HUT-
CCU specifically for your Ike. To do this, one must open the HUT-CCU and set a dip switch
as follows:

Sony/Hitachi

Ikegami

SW1

off

on

SW2

off

on

SW3

on

off

SW4

off

off


Either approach to enabling Ikegami CCU operation is valid. The choice is up to you,
although single fiber mode may make some camera system features unavailable.

Note that with some Sony camera systems, the CCU may report an open cable condition.
Despite this, the system will work normally, so you can safely ignore this warning.


3. Specifications

.

SDI Standards Supported, repeater

SMPTE 259M/292M/297M/425M, DVB/ASI

SDI Added Jitter, repeater

< .03 UI, < 1 MHZ

Laser Safety, repeater

Class 1

Optical Connectors, CAM HUT

SMPTE 311 Plug + 2 ST/UPC or LC

Optical Connectors, HUT-CCU

SMPTE 311 Receptacle + 2 ST/UPC or LC

Optical Wavelengths, nm, repeater

1310. 1550 or CWDM optional

Optical Sensitivity, repeater

-18 dBm

Optical Output Power, repeater

-2 ~ -8 dBm

Fiber Optic cable length, standard

Limited by camera/CCU

Fiber Optic cable length, repeater

Up to 20km

Indicators, CAM HUT Unit, standard

Cable open/short, HV/status

Indicators, CAM HUT Unit, repeater

As above + optical power ok/bad/laserfail

Electrical Output, CAM HUT Unit

230VAC @ up to 250VA, active,
24VAC @ up to25VA, standby

Power Requirement, CAM HUT Unit

115/230VAC, 50/60HZ, 260VA

Power Requirement, HUT CCU Unit

Steals power from CCU

Operating Temperature

0 to 70 deg C

Certifications

FCC class A and UL/CE

Dimensions, CAM HUT unit

3.5” H x 5.5” W x 10.5” D

Weight, CAM HUT unit

10 pounds

Dimensions, Base unit

2.0” H x 2.5” W x 7.0” D

Weight, Base unit

0.5 pound