To avoid having to set the Ikegami CCUs for single fiber mode, you can configure the HUT-
CCU specifically for your Ike. To do this, one must open the HUT-CCU and set a dip switch
as follows:
Sony/Hitachi
Ikegami
SW1
off
on
SW2
off
on
SW3
on
off
SW4
off
off
Either approach to enabling Ikegami CCU operation is valid. The choice is up to you,
although single fiber mode may make some camera system features unavailable.
Note that with some Sony camera systems, the CCU may report an open cable condition.
Despite this, the system will work normally, so you can safely ignore this warning.
3. Specifications
.
SDI Standards Supported, repeater
SMPTE 259M/292M/297M/425M, DVB/ASI
SDI Added Jitter, repeater
< .03 UI, < 1 MHZ
Laser Safety, repeater
Class 1
Optical Connectors, CAM HUT
SMPTE 311 Plug + 2 ST/UPC or LC
Optical Connectors, HUT-CCU
SMPTE 311 Receptacle + 2 ST/UPC or LC
Optical Wavelengths, nm, repeater
1310. 1550 or CWDM optional
Optical Sensitivity, repeater
-18 dBm
Optical Output Power, repeater
-2 ~ -8 dBm
Fiber Optic cable length, standard
Limited by camera/CCU
Fiber Optic cable length, repeater
Up to 20km
Indicators, CAM HUT Unit, standard
Cable open/short, HV/status
Indicators, CAM HUT Unit, repeater
As above + optical power ok/bad/laserfail
Electrical Output, CAM HUT Unit
230VAC @ up to 250VA, active,
24VAC @ up to25VA, standby
Power Requirement, CAM HUT Unit
115/230VAC, 50/60HZ, 260VA
Power Requirement, HUT CCU Unit
Steals power from CCU
Operating Temperature
0 to 70 deg C
Certifications
FCC class A and UL/CE
Dimensions, CAM HUT unit
3.5” H x 5.5” W x 10.5” D
Weight, CAM HUT unit
10 pounds
Dimensions, Base unit
2.0” H x 2.5” W x 7.0” D
Weight, Base unit
0.5 pound