4. Installation
4-1
4.1 Location and Installation
Ventilation
Exhaust gas from the engine is poisonous, and could cause
death when inhaled.
Avoid using the machine in an insufficiently ventilated building or
tunnel.
Do not position the exhaust gas outlet in direction of a person or
a house.
PC002
The machine has to be parked horizontally on a level place.
In case the machine has to be parked on a slope, place it across
grade so that the machine does not tend to roll downhill.
Grade on a slope shall be within 15 degrees
Be sure to put one set of chocks“1”to the wheels.
A000054
The machine should be operated in following conditions:
Ambient temperature
・・・・・・・
5°F to 104°F (-15°C to +40°C)
Humidity
・・・・・・・・・・・・・・・・・
Less than 90%
Altitude
・・・・・・・・・・・・・・・・・・
Lower than 1,500 m above sea level
Install the machine in a place with good ventilation, lower temperature and with surroundings as
dry as possible.
If more than two machines are placed parallel in operation, keep enough distance so that exhaust
air from one machine does not affect the other one.
Also, a machine has to be installed in the environment where fresh air is always available.
Keep enough space around the unit for inspection and maintenance access.