5. Generator Use
Warnings and cautions
n
To prevent electrical shock from faulty appliances, the generator should be
grounded. Connect a length of heavy cable between the generator's ground
terminal and an external ground source.
n
Connections for standby power to a building's electrical system must be made
by a qualified electrician and must comply with all applicable laws and electrical
codes. Improper connections can allow electrical current from the generator to
back feed into the utility lines. Such back feed may electrocute utility company
workers or others who contact the lines during a power outage. When utility
power is restored the generator may explode, burn, or cause fires in the
building's electrical system.
n
Do not connect the generator to an automatic transfer device. Severe damage to
the inverter module may result.
e. Push the choke knob in to the OPEN position as the engine warms up.
CHOKE KNOB
n
Do not operate the generator when the ambient temperature is below -20° F
(-29°)
n
Do not operate the generator when the ambient temperature is above 113° F
(45° C)
GROUND
TERMINAL
n
The total wattage of all appliances connected must be considered.
n
Limit operation requiring maximum power to 30 minutes. For continuous
operation do not exceed the rated power of 2800 watts or 23.3 amps.
n
Do not exceed the current limit specified for any one receptacle.
n
Do not connect the generator to a household circuit. This could cause the
damage to the generator or to electrical appliances in the house.
n
Do not modify or use the generator for other purpose than it is intended for.
n
Do not attempt to connect generators in parallel.
n
Do not connect an extension to exhaust pipe.
n
When an extension cable is required, make sure you use the proper size and
length.
n
16 Gauge Cords- Any 16 gauge cord between 0-100 feet (0-30.5 meters) long
will adequately handle tool and appliance loads up to 10 amps