Owner’s Manual - page 8

amperage control set to

“Panel” or “Standard” depending on power supply.

Turn the Cobramatic® power switch to the

“ON” position and the Posa Start

switch to the

“OFF” position.

Adjust power source to desired amperage for your weld condition.
Press gun trigger and adjust wire feed speed at gun to match current setting.

If approximate wire feed speed is not known, it is better to start with excess

wire feed rather than too little, in order to prevent possible damage to the

contact tip.
Turn Posa Start switch to the

“ON” position. Press torch trigger and, using

Run-in Speed Control, adjust wire feed speed to approximately

10% of weld-

ing wire speed set at torch.
Strike an arc; if the wire stubs out, reduce wire feed rate at gun, or increase

amperage setting on power source.

NOTE:

Because the Posa Start Run-in Speed always remains a percentage

of the actual welding wire feed rate, the Posa Start run-in speed

will always slow down or speed up proportional to any

adjustment you now make at the gun. Therefore, if you slow down

the welding wire feed speed, you will have to increase

the Run-in Speed setting.

Section C

OPTIONAL KITS

The following is a list of Optional Kits available for the Cobramatic

®

Wire

Feeder.
A detailed description of each kit is given later in this section.

P/N

Description

005-0674 Gas Purge/Trigger Latch Kit

005-0675 Water Pressure Kit

005-0674 Gas Purge/Trigger Latch Kit

The Gas Purge/Trigger Latch Kit is a dual function kit. The kit includes an

easy to install interface control PC board, a 24VAC solenoid for pre and post

purge control, a modified valve stem for the welding torch and, a front panel

switch for activating the Trigger Latch mechanism.
The gas control times have been preset to 0.5 seconds pre-purge and 1.0

seconds post-purge. This offers an optimum amount of inert gas shielding

prior to striking the arc and after the arc has been extinguished.
The Trigger Latch mechanism gives the operator the flexibility of normal

trigger operation (pull trigger to weld - release trigger to stop). This also

offers the comfort of latched trigger operation (pull trigger once to latch and

weld - pull trigger again to unlatch and stop).
005-0675 Water Pressure Kit

By monitoring the pressure from the water recirculator, the switch uses the

pressure as the key safety element in protecting the torch from overheating

Section C

(Continued)

CAUTION:

Do Not operate this wire feeder on a power source having a high-frequency

starting circuit before making sure that the high frequency portion of the

power source is turned off.

Failure to take this precaution will cause permanent

damage to the Posa Start circuitry.